Evolution of Residential Lighting

Regal Home Inspections, LLC recently did an inspection in Matawan, NJ.  The house was over 100 years old and it’s a time capsule for the evolution of residential illumination (Lighting).  In this home were at least 3 distinct technologies seen.  Assuming that they never used candles, the original illumination in the house was gas lights. Pipes were installed that delivered gas to the wall fixture. An open flame illuminated the area. There’s a movie, Gas Light where someone uses a gas light to try to convince another that they’re crazy. The phrase was popularized in 2022 making, “Gaslight” one of the words of the year.

An old gas light fixture. Estimate to be Pre-1920s.

 

This was in the attic of this Matawan house.  Also in the house was Knob & Tube wiring.

Knob and Tube wiring being tested with a voltage detector. The circuit was energized.

The next iteration of residential wiring was knob and tube. Knob and Tube (KnT) wiring was the state-of-the-art around the 1920’s and 1930’s. We’ve found a lot of knob and tube wiring during the nearly 4000 inspections over the years.  In addition to KnT being old, insurance companies don’t like the added risk that it causes. KnT circuits are usually ungrounded. There is no ground wire. That wasn’t much of an issue in the 1930s but 21st century electronics (Computers, modern TVs, etc.) all must be grounded.

KnT circuits have, knobs (Seen in all three photos starting with the one immediately to the left and the two following). The knobs are ceramic and secure the individual wires.

The tubes are also ceramic and are used when the wires have to be installed through wood joists or rafters. If you’re considering buying a home built in the 1940s and earlier, MAKE SURE to have an inspection and use an inspector, like Regal Home Inspections, LLC, that knows what to look for in determining if KnT is or may be present.  If KnT is present, a licensed electrician must evaluate and replace all KnT wiring.

KnT was also seen in the attic. Modern electrical cable has the hot wire, neutral wire and ground inside one jacket (aka casing). KnT, as seen here, has two separate conductors.
KnT is often buried in insulation which is also bad.

 

 

 

 

 

 

 

 

Circa the 1940s & 50s, cloth sheathed cables and conductors were used. The wire, in many cases, was tinned-copper. That is a solid copper conductor with a very thin, tin coating.  There’s still a lot of this type & era cable in service. Except for the fact that the insulating materials on the wires can become brittle and break, it’s not an issue like KnT and the aluminum (Next topic).  If there are indications of the insulating materials deteriorating, a licensed electrician must evaluate and repair.

Around the early 1960s more common Non Metallic (NM) cables were used. Key among this era of cables is that all** the conductors were copper. These are still available and the predominant type of electrical cables used. One brand name is ROMEX and the entire category of NM cables are often generically referred to as, “Romex”.  We also see some metal, armor jacketed cables commonly called, “BX”.  BX is still available today and commonly used. Some jurisdictions, such as New York City/Manhattan, still requires BX or metal, armor jacketed cables today.  The NM and BX cables described in this paragraph are STILL the state of the art.  **However, there was a brief period when The Great Garden State allowed solid aluminum conductors in NM cables. From what I’ve been told, toward the end of the Vietnam War some jurisdictions (Including NJ) allowed solid conductor aluminum to be used. From about 1967 through about 1974 it was an option for builders and electricians. My home, built in 1972, had nearly all solid conductor aluminum wire when we moved into it in 1991. If you’re planning to purchase a home build 1967 – 1974, make sure to select an inspector that is aware of the use of aluminum in that era. For a few reasons, aluminum was known to cause fires. Insurance companies don’t like it and it’s expensive to replace.  A technique called, “Pig-tailing” is often used to mitigate the issues with aluminum.  For my home, I decided to replace it all with solid copper, BX cable which is superior to the electrical code for NJ. There is a little, modern, copper, NM cable but the vast majority is copper conductor, BX.

Flippin’ Flippers

Flippin’ Flippers

by Frank J. Delle Donne  

October, 2022

Flipping houses has become an occupation for some. There are many homes that have been restored and updated by investors and DIYers. Many of them are very nice. However, as home inspectors, we’ve come across a number of flipped houses that fall under the category of what I call “Buyer Beware”. One such example was inspected October, 2022.

Due to some findings at this house, I was motivated to write this article as a word of caution to prospective buyers of flipped houses and a strong word of encouragement to hire a professional, licensed home inspector.  Your due diligence includes the inspection of the house including a termite inspection, sewer scope and tank sweep at least.  Most flipped houses are not occupied when you are thinking of buying it and have been empty for a while. Many flipped homes are old.

The standard, New Jersey home inspection covers structure, roof, electric, plumbing, etc. All very important things. I am also licensed to conduct a termite inspection and both inspectors here at Regal Home Inspections are also licensed to conduct radon tests.  Commencing in the very near future, one inspector at Regal Home Inspections, LLC will also be NJ licensed/certified to perform LEAD PAINT testing as well.

From what I’ve learned, anecdotally, many mortgage companies require a termite inspection. Even if yours does not, it’s very important that you hire a thorough inspector for Wood Destroying Insects (WDI).  WDI usually include termites, carpenter ants and carpenter bees. There are others but these are the three, most common.

While most houses should have a radon test, Monmouth County, for example, has a number of towns that are classified by the NJ DEP as, “High radon potential” areas. A few towns in Middlesex County and Somerset County. No towns in Ocean County are classified as high radon potential areas but we have seen homes with levels of radon that require mitigation. A radon test is important for a home you’re buying and periodic radon tests are important for occupied homes.

Back to the, “Flippin’ Flippers.”

The flip-house we recently did in Monmouth County had a nice looking kitchen and nicely renovated bathrooms and floors, etc. But what exists outside of the obvious is what matters. For this home, the major issues included:

Extensive, structural damage in the basement from termites.

Structural damage due to bad trade-practices in the crawl space and

Very poor implementation of aspects of the roof/plumbing vents and fan venting to the outside.

Termite Damage – Sometimes, termite damage is hard to find. It’s often limited and in a small area. Sometimes the indications are seen outside and sometimes inside. In this case, there was termite damage in a number of floor joists and in the subfloor. The termites rendered a number of joists as worthless for their intended purpose. Consequently, floors were no longer level and the structure of the house was compromised. Of course, following the NJ HI standards of practice, this is a material defect.  I’m going out on a limb and speculate that the flipper didn’t do their own inspection because this would have/should have been found.  In our report to the client we identified the problem, told them why it was important – damages the structure/reduces structural integrity – and advised them on what to do next. In this case it’s getting in an expert to provide a quote to repair and replace all the damaged wood so they can negotiate the purchase price with the flipper and receive some concession.

 

 

 

 

 

 

 

 

 

 

 

 

Structural Damage – While crawl spaces are not places I enjoy going, as I sometimes tell people, “Going into the crawl space was, “worth the price of admission”. In this same, flip-house there were two joists, under a bathroom no less, that had notches and split. These joists are holding up the weight of the tub and toilet and they are now capable of supporting a load that’s only a fraction of the joists’ intended strength.

Joist is poorly notched and now a split is forming from the weak point.
This notch significantly weakens the joist. Furthermore, both of these joists are below a bathroom. There appear to be some sagging in the joist at the notch. That’s understandable.

 

 

 

 

 

 

 

 

Roof issue. This is one for the Hall of Shame in my opinion. A sincere, “Thank you” to the flipper for making it so easy to identify.  From the outside of the house there were two elements of the roof that caught my attention. Now please note, the NJ home inspection laws require inspectors have an 11 foot ladder. Following the ladder’s safety instructions, that means I can’t get on a roof that more than, approximately 8 feet off the ground.  I also carry a 22 foot ladder but for this home, that too was not long enough. So, I use the telephoto lens of my camera and zoom into the roof as close as possible.

The first 2 photos below caused some concern when seen from the outside.

 

 

 

 

 

 

When I went into the attic, I could see what was actually done. To give you an idea, my first reaction was to use a descriptive word for the actions of the flipper such as, “egregious”. A quick Google search for the definition of egregious results in, “outstandingly bad; shocking.”  Yes, that’s how I felt. My inspection partner, Brian, told me to edit that out of the report so I did. I substituted it with, “poor craftsmanship” or something similar.  The conditions still are material defects. The conditions were these…

For the pipe boot seen from the outside (Right photo above), the craftsman, inappropriately left the plumbing vent short and inside the attic and stuffed a bathroom fan’s vent together at the bottom of the pipe boot. The boot is absolutely not intended for that configuration. Someone knew they were doing that work incorrectly and in a substandard manner but did it anyway.

 

 

 

 

 

For the first photo from the roof, someone just stuck the open end of a 4 inch diameter, flexible foil vent duct through the roof! That’s basically a 4 inch diameter hole in the roof.  For both of these things, what were they thinking?

Water will enter the vent and collect at the bottom of the duct inside the attic. The potential exists for either the duct to leak onto the ceiling above or the water accumulate so much that it starts draining out of the ceiling fan in the bathroom!

 

 

 

 

 

 

 

 

Bottom line, these matters were found and properly reported back to the client. There were also other findings that require attention; Electrical, safety and maintenance items (Like clogged and loose gutters).

Bottom line, hire a capable inspection company. Although you have to pay for these things, get the inspection, oil tank sweep, sewer scope, termite inspection, radon test and even a lead paint inspection.  There are also other things that may or may not apply such as pool inspections, Level 2 chimney inspections, etc.  If you have any questions please call Brian Delle Donne at 732 740 8365 or Frank at 908 902 2590.

 

Wind Loss Mitigation Insurance Inspections

Wind Loss Mitigation Insurance Inspections | Home Inspections Colts Neck NJ

certified home inspector monmouth county njFrank J. Delle Donne, Inspector and co-owner of Regal Home Inspections, LLC, has passed the National Association of Certified Home Inspectors (NACHI) class to perform Wind Loss Mitigation inspections. Wind loss mitigation inspections are done in an attempt to save money on your home insurance in hurricane zones.  The class taken and passed is based on various Florida construction codes including Miami Dade’s codes but is an insurance industry process so the insurance company can determine if the home is less likely to sustain damage (Financial losses) in a high wind event like a hurricane.

The training requires inspection and documentation of a number of wind and projectile protection mechanisms in a home. That includes the types of windows and glazing as well as the roof structure and strapping that can help prevent a roof from being pulled from a home in a High Velocity Hurricane Zone.

Call for a quote. 908 902 2590 or email at frank07722@gmail.com

Other Services | Certified Home Inspector Monmouth County NJ

Regal Home Inspections, LLC is thermal imaging certified and offers Monmouth County NJ certified home inspections, condo inspections, estate inspections, and townhouse inspections.

It’s likely your mortgage company will require a wood-destroying insect inspection. Regal Home Inspections has the NJ DEP Core & 7B Pesticide Applicator license, so we can offer professional termite and wood-destroying insect inspections as well!

Call 908-902-2590 for your free quote or if you have any questions!